Malaria and Dengue Co-infection in Pregnancy Causing Severe Thrombocytopenia: A Case Report Highlighting Diagnostic and Management Challenges Due to Overlapping Clinical Features
Daniel Odongo *
Georgetown Public Hospital Corporation, Georgetown, Guyana.
David Alfred Younge
Georgetown Public Hospital Corporation, Georgetown, Guyana.
Nirvani Goberdhan
Georgetown Public Hospital Corporation, Georgetown, Guyana.
Goolcharan Dyal
Georgetown Public Hospital Corporation, Georgetown, Guyana.
Nirvanie Singh
Department of Obstetrics and Gynecology, Georgetown Public Hospital Corporation, Georgetown, Guyana.
Hardeo Ramdeholl
Department of Obstetrics and Gynecology, Georgetown Public Hospital Corporation, Georgetown, Guyana.
*Author to whom correspondence should be addressed.
Abstract
Background: Malaria and dengue are mosquito-borne infections that pose significant health risks during pregnancy and may adversely affect maternal and fetal outcomes. Their overlapping clinical manifestations can complicate diagnosis and delay appropriate management, particularly when both infections occur concurrently.
Aim: This case report aims to highlight the rarity of malaria and dengue coinfection in pregnancy and the importance of extensive targeted testing and prompt maternal optimisation to minimise adverse obstetric outcomes.
Case Presentation: A 22-year-old primigravida at 37 weeks and 4 days of gestation was referred after presenting with five days of headache, fever, vomiting and diarrhoea. Testing identified Plasmodium vivax malaria, and her initial platelet count was 18,000/µL. At the receiving hospital, dengue-specific IgM and IgG antibodies were positive, the platelet count was 40,000/µL, and ultrasound showed oligohydramnios with an amniotic fluid index of 4.14 cm. She was admitted to a high-dependency unit for close monitoring, clinical stabilisation and delivery planning. Management included intravenous crystalloid fluids, eight units of platelets, one unit of fresh frozen plasma and chloroquine. Following improvement in the platelet count to 60,000/µL on the third day, labour was induced using misoprostol and a transcervical Foley balloon and augmented with oxytocin. She delivered a live male infant vaginally, weighing 2,860 g, without reported immediate maternal or neonatal complications. Estimated blood loss was 225 mL. On the seventh day of admission, the platelet count had risen to 128,000/µL and the malaria smear was negative. She was discharged on the twelfth day.
Conclusion: Pregnant women diagnosed with either infection who exhibit severe symptoms should be extensively investigated for coinfection, and prompt treatment should be initiated to optimise maternal and fetal outcomes.
Keywords: Malaria and dengue coinfection, Plasmodium falciparum, Aedes egypti, dengue haemorrhagic fever, thrombocytopenia